Purpose: To initiate and adjust heparin therapy for patients receiving slow continuous dialysis.
Citations with documentation. 04.01.04
Sriram & Svirbely 1997
data
enter
lower end of normal PTT range in seconds
seconds
upper end of normal PTT range in seconds
seconds
calculate initial regimen
results
mean of PTT normal range
29.5
seconds
lower end therapeutic range
44
seconds
upper end therapeutic range
59
seconds
heparin bolus
2,000
units IV
volume D5W for constant infusion solution
mL
concentration of infusion solution desired
units per mL
amount of heparin to inject for infusion solution
10,000
units
initial infusion rate (units/hour)
units per hour
mL per hour of infusion solution
25
mL per hour
next PTT
4 hours
first review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
600
units per hour
mL per hour of infusion solution
30
mL per hour
perform next PTT in
4 hours
second review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
700
units per hour
mL per hour of infusion solution
35
mL per hour
perform next PTT in
4 hours
third review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
700
units per hour
mL per hour of infusion solution
35
mL per hour
perform next PTT in
4 hours
fourth review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
700
units per hour
mL per hour of infusion solution
35
mL per hour
perform next PTT in
4 hours
fifth review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
700
units per hour
mL per hour of infusion solution
35
mL per hour
perform next PTT in
4 hours
sixth review
enter
measured arterial PTT
seconds
measured venous PTT
seconds
evaluate
results
infusion rate
700
units per hour
mL per hour of infusion solution
35
mL per hour
perform next PTT in
4 hours
The browser does not support JavaScript. The calculations created using